Price: $149.99
FREE U.S. Shipping on orders over $25
Stock:
162
Item#: 0668
Venom Medion Dual 10 Amp Battery Charger with Audio Speakers
Venom Medion Dual 10 Amp Battery Charger with Audio Speakers
 |
 |
 |
Once again, Venom leaves the competition behind with the Venom Medion™ Dual Output DC Charging station with integrated media player.
Venom engineers listened to our Factory Team Pilots and they wanted music! So, we developed a rugged aluminum housed charger with a built-in media player featuring high definition 70mm drivers allowing you to pipe in your favorite tunes from your iPod®, iPhone®, Android® or other music player via a standard 1/8th inch stereo input.
Need charging power? No worries! This groundbreaking charger features 400 watts of power via dual 200-watt circuits allowing for simultaneous charging of two batteries up to 10 amps each. The Medion™ also features a new IR-Mode™ internal resistance test. IR-Mode™ will test each cell individually and provides single cell and total pack resistance values so you can see the real-time condition of your LiPO and LiFe battery packs. All this technology is accessible through an easy-to-read red, backlit LCD display. The Medion comes with Traxxas, EC5, EC3, Deans and Tamiya adaptor plugs.
Stop cluttering your pit table or garage with multiple devices. The Venom Medion™ comes with an ultra bright articulating LED bench light, as well as a 5V 1A USB output for charging up your portable devices.
With the Venom Medion™, the party's always in your pit!™ |
 |
 |
 |
| |
Features:
- Dual 200-watt charge circuits
- Capacity cut-off and timer safeguards
- Twin audio speakers to play music from MP3 player or smart phone
- Integrated cell balancing software for LiPO, LiFe, and LilO packs
- IR-Mode™ measures the internal resistance of Lithium battery packs
- Includes USB powered LED light
- Programmable battery profiles for up to 5 different battery types
- Charges LiPO, LiIO, LiFe, NiCD, NiMH, and PB (lead acid) batteries
- Temperature controlled cooling fans
- 5V/1A USB output to power smart phone charger or included LED Light
- Programmable thermal temp alarm with auto shut down
- Includes temp probe and balancing block
- Includes Traxxas®, EC5, EC3, Deans and Tamiya adaptor plugs
Requires 11V-18V DC Power Supply (300 Watt minimum, 400 Watt suggested).
GUARANTEEAll products are inspected and adjusted individually before leaving the manufacturer and are guaranteed to be free of material defects and manufacturing faults. General Warranty Policies
Venom products are warranted to be free of material and workmanship defects for a period of 30 days* from date of purchase for all electronic components and 90 days* for all non-electronic components. If a component is defective or was not correctly made, Venom will, at its sole discretion, repair or replace the item free of charge. This warranty does not cover normal wear and tear, crash damage, modifications, failure to perform routine maintenance, or any damages arising as a result of improper use.
Venom Lifetime Battery Replacement Plan We are so certain of the quality of our battery line that we offer a Venom Lifetime Battery Replacement Plan on all of our rechargeable battery packs. Venom will, at our discretion, replace defective batteries free of charge within a period of 1 year from date of purchase. Year 2 onward, any Venom battery can be exchanged for a brand new battery of same size and type for 30% off original retail pricing. This warranty does not cover normal wear and tear, crash or water damage, modifications, or any damages arising as a result of improper use. We reserve the right to deny replacement to any serial abusers of our policy. Important NoticeVenom assumes sole responsibility for our products; therefore, dealers should not be involved in any warranty issues. All warranty claims are to be directed to Venom Customer Service. Before returning any defective product, please contact Venom Customer Service at 800-705-0620 or customerservice@venom-group.com to receive a Return Merchandise Authorization Number. A dated & itemized sales receipt must accompany any product returned for warranty work. Release of LiabilityVenom it's affiliates, manufacturers, distributors, or retail partners shall not be held liable for any accident, injury to persons, or damage to property resulting from use, misuse, or abuse of any Venom product. In purchasing a Venom product the user agrees to accept responsibility for all such risks.
- Venom Dual 10 Amp Charger Manual
- FCC certification
- FCC Test Report
- Manual Sample:
Manual Sample:
The Venom™ Medion Dual 10 Amp Charger has default settings in the User Set menu that can be adjusted in this first step. The screen displays the following information in sequence and the user can change the value of the parameter on each screen. When you want to alter the parameter value in the program, press the Start/Enter button once. The value will start flashing. It can be changed by using the INC or DEC buttons, and finally saved by pressing the Start/Enter button once. The screen displays the nominal voltage of a Lithium battery. There are three kinds of Lithium batteries: LiFe (3.3V), LiIO (3.6V) or LiPO (3.7V). It is very important to check the battery and set up correctly for the chemistry type. If it is different from the correct value, the battery may explode during the charge process. The Venom™ Medion Dual 10 Amp Charger recognizes the cell count of Lithium batteries automatically at the beginning of the charge or discharge process to avoid erroneous settings by the user. A deeply discharged battery can be recognized incorrectly by the charger. To prevent the error, you can set the time term to verify the cell count by the processor. Normally, 10 minutes is enough to perceive the cell count correctly.
For a battery of larger capacity, you may extend the time term. If you set the time term too long for a battery of smaller capacity, the charge or discharge process may finish within the time term with the erroneous cell count. This may cause lethal results. If the processor recognizes the cell count incorrectly at the beginning of the charge or discharge process, you may extend the time. Otherwise use the default value. Delta peak of NiCD and NiMH battery This is the setting to set the sensitivity for the charger to detect the peak on a NiCD or NiMH battery. The effective value ranges from 5 to 20 mV per cell. If the trigger voltage is set higher, there is a danger of overcharging the battery. If it is set lower, there is a possibility of premature termination. Please refer to the technical specification of the battery. (NiCD default: 12mV, NiMH default: 7mV).
PLEASE REFER TO THE FULL MANUAL BEFORE OPERATING THIS CHARGER.
|
|
|
|